Investigation result:
- Dual-BlockVol hypothesis: DISPROVEN (one instance per path, correct wiring)
- Root cause: adapter wiring bug in test allocator
soak_test.go blockVSAllocate returned ReplicaDataAddr = "vs2:9333:14260"
(server + ":port" where server already has a port → three colons, invalid)
This caused setupReplicaReceiver to fail silently → no data replicated
Root cause classification: adapter/test-harness bug
- NOT a backend data visibility bug
- NOT a core-rule gap
- The engine read path works correctly (TestSyncAll_FullRoundTrip passes)
Code changes:
- qa_block_soak_test.go: fix allocator to use host:port (not server:port),
use deterministic FNV-hashed ports matching production ReplicationPorts
- qa_block_cp13_8a_test.go: 2 new integration tests proving replica reads
work through both ReadLBA and adapter.ReadAt, before and after promotion
Remaining contradiction for CP13-8 scenario on real hardware:
- The production weed cluster uses ReplicationPorts (deterministic) which
should not have this bug. If CP13-8 still fails on m01/M02, the cause
is different from this test-harness issue and needs a separate investigation.