Commit Graph
4 Commits
Author SHA1 Message Date
pingqiuandClaude Opus 4.6 3da4c19046 fix: CP13-8A — fix malformed replica address in test allocator + add read proof
Investigation result:
- Dual-BlockVol hypothesis: DISPROVEN (one instance per path, correct wiring)
- Root cause: adapter wiring bug in test allocator
  soak_test.go blockVSAllocate returned ReplicaDataAddr = "vs2:9333:14260"
  (server + ":port" where server already has a port → three colons, invalid)
  This caused setupReplicaReceiver to fail silently → no data replicated

Root cause classification: adapter/test-harness bug
- NOT a backend data visibility bug
- NOT a core-rule gap
- The engine read path works correctly (TestSyncAll_FullRoundTrip passes)

Code changes:
- qa_block_soak_test.go: fix allocator to use host:port (not server:port),
  use deterministic FNV-hashed ports matching production ReplicationPorts
- qa_block_cp13_8a_test.go: 2 new integration tests proving replica reads
  work through both ReadLBA and adapter.ReadAt, before and after promotion

Remaining contradiction for CP13-8 scenario on real hardware:
- The production weed cluster uses ReplicationPorts (deterministic) which
  should not have this bug. If CP13-8 still fails on m01/M02, the cause
  is different from this test-harness issue and needs a separate investigation.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-03 11:47:41 -07:00
pingqiuandClaude Opus 4.6 ac962fc833 fix: CP13-2 — relax contract to host:port, add BlockService-level test
Two fixes:
1. Rename advertisedIP → advertisedHost throughout, relax contract from
   "always a real IP" to "routable host from -ip flag (IP or resolvable
   hostname)". This matches the actual -ip flag semantics which accepts
   both IP addresses and server names.

2. Add TestCP13_2_BlockService_AdvertisedHost_NotOpaqueID that hits the
   actual production wiring: BlockService with opaque localServerID +
   routable advertisedHost → setupReplicaReceiver → verify exported
   addresses use the routable host, not the opaque ID.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-02 21:12:38 -07:00
pingqiuandClaude Opus 4.6 4bdf6c604e fix: CP13-2 — use advertisedIP (routable), not localServerID (opaque)
Bug: setupReplicaReceiver derived the advertised host from localServerID,
which can be an opaque string (from -id flag, e.g., "my-custom-server-id").
This would publish unusable endpoints like "my-custom-server-id:14260".

Fix:
- volume_server_block.go: add advertisedIP field (always a real IP from
  -ip flag), use it instead of localServerID for replica canonicalization
- volume.go: wire *v.ip → blockService.SetAdvertisedIP() at startup
- blockvol.go: StartReplicaReceiver variadic advertisedHost unchanged

Proof (sync_all_bug_test.go TestBug3, 4 sub-cases):
- fallback: wildcard bind without advertisedHost → outbound-IP
- advertisedHost: explicit IP appears in exported addresses
- StartReplicaReceiver_API: public API forwards host correctly
- opaque_identity_not_routable: proves opaque string produces
  non-routable address, confirming production must use advertisedIP

Identity vs transport separation preserved:
- localServerID: stable identity for V2 control (may be opaque)
- advertisedIP: routable IP for transport endpoints (always real IP)

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-02 20:51:47 -07:00
pingqiuandClaude Opus 4.6 643a5a1074 feat: Phase 12 P3+P4 — diagnosability surfaces, perf floor, rollout gates
P3: Add explicit bounded read-only diagnosis surfaces for all symptom classes:
- FailoverDiagnostic: volume-oriented failover state with per-volume
  DeferredPromotion/PendingRebuild entries and proper timer lifecycle
- PublicationDiagnostic: two-read coherence check (LookupBlockVolume vs
  registry authority) with computed Coherent verdict
- RecoveryDiagnostic: minimal ActiveTasks surface (Path A)
- Blocker ledger: 3 diagnosed + 3 unresolved, finite, from actual file
- Runbook references only exposed surfaces, no internal state

P4: Add bounded performance floor + rollout-gate package:
- Engine-local floor measurement with explicit IOPS gates per workload
- Cost characterization: WAL 2x write amp, -56% replication tax
- Rollout gates with semantic cross-checks against cited evidence
  (baseline numbers, transport/network matrix, blocker counts)
- Launch envelope tightened to actually measured combinations only

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-02 16:20:22 -07:00