Adds per-replica state reporting in heartbeat so master can identify
which specific replica needs rebuild, not just a volume-level boolean.
New ReplicaShipperStatus{DataAddr, State, FlushedLSN} type reported
via ReplicaShipperStates field on BlockVolumeInfoMessage. Populated
from ShipperGroup.ShipperStates() on each heartbeat. Scales to RF=3+.
V1 constraints (explicit):
- NeedsRebuild cleared only by control-plane reassignment (no local exit)
- Post-rebuild replica re-enters as Disconnected/bootstrap, not InSync
- flushedLSN = checkpointLSN after rebuild (durable baseline only)
4 new tests: heartbeat per-replica state, NeedsRebuild reporting,
rebuild-complete-reenters-InSync (full cycle), epoch mismatch abort.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Flusher now holds WAL entries needed by recoverable replicas.
Both AdvanceTail (physical space) and checkpointLSN (scan gate)
are gated by the minimum flushed LSN across catch-up-eligible
replicas.
New methods on ShipperGroup:
- MinRecoverableFlushedLSN() (uint64, bool): pure read, returns
min flushed LSN across InSync/Degraded/Disconnected/CatchingUp
replicas with known progress. Excludes NeedsRebuild.
- EvaluateRetentionBudgets(timeout): separate mutation step,
escalates replicas that exceed walRetentionTimeout (5m default)
to NeedsRebuild, releasing their WAL hold.
Flusher integration: evaluates budgets then queries floor on each
flush cycle. If floor < maxLSN, holds both checkpoint and tail.
Extent writes proceed normally (reads work), only WAL reclaim
is deferred.
LastContactTime on WALShipper: updated on barrier success,
handshake success, and catch-up completion. Not on Ship (TCP
write only). Avoids misclassifying idle-but-healthy replicas.
CP13-6 ships with timeout budget only. walRetentionMaxBytes
is deferred (documented as partial slice).
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replaces binary degraded flag with ReplicaState type:
Disconnected, Connecting, CatchingUp, InSync, Degraded, NeedsRebuild.
Ship() allowed from Disconnected (bootstrap: data must flow before
first barrier) and InSync (steady state). Ship does NOT change state.
Barrier() gating:
- InSync: proceed normally
- Disconnected: bootstrap path (connect + barrier)
- Degraded: reconnect both data+ctrl connections, then barrier
- Connecting/CatchingUp/NeedsRebuild: rejected immediately
Only barrier success grants InSync. Reconnect alone does not.
IsDegraded() now means "not sync-eligible" (any non-InSync state).
InSyncCount() added to ShipperGroup.
dist_group_commit.go: removed AllDegraded short-circuit that
prevented bootstrap. Barrier attempts always run — individual
shippers handle their own state-based gating.
8 CP13-4 tests + TestBarrier_RejectsReplicaNotInSync flips FAIL→PASS.
All previously-passing baseline tests remain green.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Barrier response extended from 1-byte status to 9-byte payload
carrying the replica's durable WAL progress (FlushedLSN). Updated
only after successful fd.Sync(), never on receive/append/send.
Replica side: new flushedLSN field on ReplicaReceiver, advanced
only in handleBarrier after proven contiguous receipt + sync.
max() guard prevents regression.
Shipper side: new replicaFlushedLSN (authoritative) replacing
ShippedLSN (diagnostic only). Monotonic CAS update from barrier
response. hasFlushedProgress flag tracks whether replica supports
the extended protocol.
ShipperGroup: MinReplicaFlushedLSN() returns (uint64, bool) —
minimum across shippers with known progress. (0, false) for empty
groups or legacy replicas.
Backward compat: 1-byte legacy responses decoded as FlushedLSN=0.
Legacy replicas explicitly excluded from sync_all correctness.
7 new tests: roundtrip, backward compat, flush-only-after-sync,
not-on-receive, shipper update, monotonicity, group minimum.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>