 Ping QiuandClaude Opus 4.6
|
8b2b5f6f66
|
feat: Phase 6 CP6-3 -- failover + rebuild in Kubernetes, 126 tests
Wire low-level fencing primitives to master/VS control plane and CSI:
- Proto: replica/rebuild address fields on assignment/info/response messages
- Assignment queue: retain-until-confirmed (Peek+Confirm), stale epoch pruning
- VS assignment receiver: processes assignments from HeartbeatResponse
- BlockService replication: ProcessAssignments, deterministic ports (FNV hash)
- Registry replica tracking: SetReplica/ClearReplica/SwapPrimaryReplica
- CreateBlockVolume: primary + replica, enqueues assignments, single-copy mode
- Failover: lease-aware promotion, deferred timers with cancellation on reconnect
- ControllerPublish: returns fresh primary iSCSI address after failover
- Recovery: recoverBlockVolumes drains pendingRebuilds, enqueues Rebuilding
- Real integration tests on M02: failover address switch, rebuild data
consistency, full lifecycle failover+rebuild (3 tests, all PASS)
Review fixes (12 findings, 5 High, 5 Medium, 2 Low):
- R1-1: AllocateBlockVolume returns replication ports
- R1-2: setupPrimaryReplication starts rebuild server
- R1-3: VS sends periodic block heartbeat for assignment confirmation
- R2-F1: LastLeaseGrant set before Register (no stale-lease race)
- R2-F2: Deferred promotion timers cancelled on VS reconnect
- R2-F3: SwapPrimaryReplica uses RoleToWire instead of uint32(1)
- R2-F4: DeleteBlockVolume deletes replica (best-effort)
- R2-F5: SwapPrimaryReplica computes epoch atomically under lock
- QA: SetReplica removes old replica from byServer index (BUG-QA-CP63-1)
126 CP6-3 tests (67 dev + 48 QA + 8 integration + 3 real).
Cumulative Phase 6: 352 tests. All PASS.
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
|
2026-03-05 00:52:05 -08:00 |
|
 Ping QiuandClaude Opus 4.6
|
80801b0fac
|
feat: Phase 3 — performance tuning, iSCSI session refactor, store integration
Phase 3 delivers five checkpoints:
CP1 Engine Tuning: BlockVolConfig tunables, 256-shard DirtyMap, adaptive
group commit (low-watermark immediate flush), WAL pressure handling with
backpressure and ErrWALFull timeout.
CP2 iSCSI Session Refactor: RX/TX goroutine split with respCh (cap 64),
txLoop for serialized response writes, StatSN assignment modes. Login
phase stays single-goroutine; full-duplex after login.
CP3 Store Integration: BlockVolAdapter (iscsi.BlockDevice interface),
BlockVolumeStore management, BlockService in volume_server_block.go,
CLI flags (--block.listen/dir/iqn.prefix), sw-block-attach.sh helper.
CP5 Concurrency Hardening: WAL reuse guard (LSN validation in ReadLBA),
opsOutstanding counter with beginOp/endOp + Close drain, appendWithRetry
shared by WriteLBA and TrimLBA, flusher LSN guard in FlushOnce.
Bug fixes (P3-BUG-2–11): unbounded pending queue cap, Data-Out timeout,
flusher error logging, GroupCommitter panic recovery, Close vs concurrent
ops guard, target shutdown race, WAL-full retry vs Close, WRITE SAME(16)
for XFS, MODE SENSE(10) + VPD 0xB0/0xB2 for Linux kernel compatibility.
797 tests passing (517 engine + 280 iSCSI), go vet clean.
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
|
2026-03-01 10:43:34 -08:00 |
|