The settings card stops being a Modbus card
Both transports that read the charger can also be told things, so both get the card now. Modbus has four writable registers and keeps the four controls it had. The cloud has the charger's whole settings group — two dozen of them, everything the Anker app sets short of the card list — and they were readable in the readings card and settable nowhere. Drawn from a table rather than written out one control at a time, because the charger's commands own sets of fields and take a command whole: a schedule frame carrying only its switch is a schedule whose times have just been set to midnight. So a section is one command, its fields are sent together, and Apply is per section. Only what the charger has reported gets a control — a blank box that writes whatever it was left at is worse than no box when the value travels as a sibling. The meter and monitor the balancing features watch stay read-only: there is no command for them, and what their modes select is undocumented. The phase select offers the automatic and single-phase this command carries, and shows a reported three-phase rather than reading as something the charger did not say. Nothing left the readings card. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
1 parent
3064bff8ad
commit
9d4aecb668
4 files changed
+369
-2
No files matched your search
@@ -154,6 +154,18 @@
|
||||
"timeoutHint": "Mindst {n} sekunder. Laderen falder tilbage til sin egen strategi, hvis intet skriver inden for tiden.",
|
||||
"settingsReported": "Rapporteret, kan ikke indstilles",
|
||||
"settingsReportedHint": "Laderen rapporterer disse; Modbus-kortet har intet register til at skrive dem. Ret dem i Anker-appen.",
|
||||
"blockCharging": "Opladning",
|
||||
"blockSchedule": "Tidsplan",
|
||||
"blockBalancing": "Belastningsbalancering",
|
||||
"blockSolar": "Sol",
|
||||
"blockPanel": "Panel og lys",
|
||||
"blockLocal": "Lokalt netværk",
|
||||
"windowStart": "Start",
|
||||
"windowEnd": "Slut",
|
||||
"reset": "Fortryd",
|
||||
"cloudSettingsHint": "Laderens egne indstillinger, skrevet via Anker-skyen. Et afsnit er én kommando til laderen, så dets felter anvendes samlet.",
|
||||
"cloudSettingsReportedHint": "Laderen rapporterer disse; ingen kommando skriver dem. Hvad de to tilstande og flaget vælger, er udokumenteret, så de vises som de tal, de er.",
|
||||
"modbusOffWarning": "Med Modbus TCP-serveren slået fra svarer laderen ikke længere på det lokale netværk, og Modbus-styringstilstanden har intet at ringe op.",
|
||||
"device": "Enhed",
|
||||
"alarms": "Alarmer",
|
||||
"phase": "Fase",
|
||||
|
||||
Reference in new issue
Block a user