The Anker Solix connector was read-only (cloud monitoring only). Add an
OCPP 1.6J control path with a per-user, cascading control mode:
- off monitoring only (default, unchanged behavior)
- own DriverVault is the charger's Central System (full control)
- proxy DriverVault relays to Anker's cloud and injects commands
New internal/ocpp subsystem (stdlib-only, hand-rolled RFC 6455): a CSMS
with session management, inbound dispatch, and typed control commands
(RemoteStart/Stop, SetChargingProfile current limit, ChangeAvailability,
Reset, UnlockConnector, TriggerMessage, Get/ChangeConfiguration). Own- and
proxy-mode paths are verified end-to-end against a simulated charge point.
The charger connects to /ocpp/{serial}, authenticated with OCPP Basic auth
(serial + a per-charger control token) resolved to the owning user via an
in-memory token index. Control REST endpoints mirror the monitoring ones and
reuse the same cascade gate plus a live-session check. controlMode is a new
cascade field (global -> org -> user) advertised as a select on the plugin.
Frontend: control-mode select + provisioning card in Settings, and a real
Start/Stop/limit/reset control panel in Charging, gated on the active mode.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>