tajniak81andClaude Opus 5 4ff6242c8f The last message in the map, and it reboots the charger
0108 was the one thing in the MQTT inventory nobody had wired: the device
power mode, whose single documented value restarts the charger. It is the
only way to reboot a charger that is on neither a CSMS nor the local
network — which is most of them — so the cloud transport sends it now,
and "reset" reaches it too, since that is what the OCPP path has always
called the same act.

Nothing waits for a confirmation: the device that would send it is the
device rebooting, so the command answers at once and says the charger
drops off the cloud for about a minute. The gate is unchanged and now
covers both spellings — an explicit confirm plus a password step-up,
audited either way. Modbus still refuses, because no register does this,
but its refusal now names both transports that can rather than only the
CSMS.

Both clients already had the reset button and its password prompt; they
were hidden in every mode that reads the device, which is why the cloud
never showed one. Modbus is now the only mode without it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-02 23:15:12 +02:00
tajniak81andClaude Opus 5 90558d60b2 What the app can set, the cloud connection can set
The broker transport could move a session along — start, stop, boost, skip the
delay, cap the current — and nothing else. Everything the charger is actually
configured with sat one field away in the same messages we were already
decoding: the schedule it charges on, the plug lock, auto-start, the LED, load
balancing, solar charging, and the Modbus server the local transport depends on.
Readable, and unreachable.

The obstacle was never the cloud, it was the shape of the protocol. A setting is
not a register write. It is a *command*, and a command owns a set of fields
inside a message type — mostly one, but five own several, and the charger reads
the whole command as the new truth. A light-off schedule sent carrying only its
switch is a schedule whose start and end have just been set to midnight. So a
grouped write resends the siblings the caller did not name, using the values the
charger itself last reported, and refuses when it has never reported them. That
last part is not caution for its own sake: load balancing and solar charging
carry the serial of the meter they watch, and nothing outside the charger knows
it. An empty one would be adopted.

Those values do not arrive with the telemetry, either. The fast 0410 stream a
realtime trigger turns on carries none of them — the settings come on 0405, 0840
and 0900, which the charger sends when it has something to acknowledge. So a
grouped write may have to send a trigger first purely to make the charger talk
about itself, and says so plainly when even that produces nothing.

Everything a caller supplies is encoded before the cloud is touched at all. A
request naming one bad value changes nothing rather than half of what it asked
for, and a mistyped setting costs a validation error instead of a sign-in, a
certificate fetch and a broker connection to be told no.

mqttsettings.go holds one table and it is the only place a setting is defined:
the wire field, the name a caller uses, the state key its current value comes
from, and how a value becomes bytes. The names are the snapshot's own, so a
caller can read a status, change one entry and send it back. The existing limit
command now builds its frame from that table too rather than encoding field a8 a
second time.

Reading grew to match. The frame decoder gains the fields the grouped writes must
carry back — the two load-balance settings, both monitor serials, the solar
monitoring mode — plus the swipe gestures, and the snapshot exposes the rest of
what is now writable. One name was wrong and is corrected: field d9 was called
chargingMode after the Modbus register at 20088, but the reference has it as the
solar charging mode, so it becomes solarChargeMode and moves in beside the solar
settings. A mislabelled reading is bad; a mislabelled writable field is worse.

Over HTTP it is one action rather than a dozen, because the charger groups the
fields anyway: POST .../settings with a settings object, and settings sharing a
command travel in one frame instead of overwriting each other. The other two
transports refuse it by name and say which one has it, the way they already
refuse each other's commands. The audit trail records the values, not just that
a write happened — a setting that changes what the charger will draw, or whether
it answers on the LAN at all, is worth being able to trace afterwards.

Two things worth saying plainly. This is built from the reference project's
message maps and checked against its own frame layout, not against hardware —
there is no charger on this end to point it at. And modbusEnabled is a loaded
gun: writing it off stops the charger serving the register map, and the way back
is this transport, or the app.

The ignore rule for the local Modbus map artifact widens to the protocol maps
that now sit beside it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-02 18:28:45 +02:00
tajniak81andClaude Opus 5 576df58776 Go the way the owner's phone already goes
Control had two transports and neither fitted the ordinary customer. OCPP waits
for the charger to dial in, which needs a public endpoint it can reach, a
certificate, and a firmware willing to talk to our CSMS. Modbus TCP dials the
charger, which needs the server on the charger's own network. Between them they
cover a charger we host and a charger we stand next to; the common case is a
charger behind someone else's router, and that had nothing.

It was never unreachable, though. The charger holds a connection open to Anker's
own broker — it is how the mobile app drives it from anywhere, and it is the
mqttStatus register the Modbus snapshot has been reporting all along. So a third
control mode joins that broker as the account: get_user_mqtt_info issues a client
certificate, mTLS to aiot-mqtt-eu.anker.com:8883, and commands go out on the same
topics the app publishes on. Nothing on the customer's side has to be forwarded,
addressed or certificated.

What travels is not an API call. The payload is a JSON envelope around a base64
binary frame the device itself speaks — marker, little-endian length, message
type, name/length/type/value fields, XOR checksum — so mqttframe.go is a codec
rather than a client, written from the message maps in anker-solix-api and
anchored on the one frame that project documents byte for byte. A frame whose
fields do not tile exactly up to the checksum is refused rather than half-read:
these arrive over a link we do not control, and a truncated frame must not read
as a charger reporting zeros.

Two of the charger's habits shape the rest. It publishes nothing unless asked, so
a status read arms a telemetry trigger and waits for the next frame, and a poll
inside that window answers from what has since arrived. And a broker connection
costs a fetched certificate and a TLS handshake while the plugin manager builds a
throwaway instance per request — so the connection lives on the account's shared
session beside the auth token, for exactly the reason the token lives there, and
closes itself after five idle minutes.

The transport also sees two signals no other one does: the boost flag, and the
plug and start countdowns. The package doc has said since the first commit that
they are never set and the derived mode must do without them. Here they are set,
so a charger that has been told to start and is counting down a delay says so
rather than sitting in "preparing", and "skip the delay" is offered only while
there is a delay to skip.

The clients generalise instead of growing a second layout. Both snapshots name
the same quantities the same way, so what was Modbus-only in the readouts is now
whichever transport read the charger — ModbusStatus becomes ChargerStatus on the
phone, mb becomes dev on the web. What each transport can be *told* still
differs, and the buttons branch on that: reset and clear-limit stay with OCPP,
the timeout and phase registers with Modbus, skip-delay with the cloud. A command
a transport has no equivalent for is refused by name, saying which one has it.

The cost is worth saying plainly. This leans on Anker's cloud being up and on an
unofficial protocol the app may change under us, where Modbus leans on nothing
but the LAN. And it is checked against the reference implementation's own worked
example rather than against hardware — there is no charger on this end to point
it at.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-02 16:47:10 +02:00
tajniak81andClaude Opus 5 f7472bada3 Reach the charger where it is, instead of waiting for it to call
OCPP asks the charger to dial us: a public endpoint, a TLS certificate, and a
route in through the customer's router. Our own handler then demanded two more
things the V1 does not offer — TLS on a charger that connects over ws://, and
Basic auth credentials the Anker app has no field for — so every connection was
turned away before the upgrade.

Anker publishes a Modbus TCP register map for this charger, and it inverts the
problem: we dial the charger, on its own network, with no inbound reachability
to arrange. That works for a charger behind a router that OCPP cannot reach at
all.

internal/modbus is the protocol, hand-rolled against the spec like the MQTT and
WebSocket clients beside it. The plugin's modbus.go is the V1's map: the same
0-8 status enum the cloud already reports, per-phase measurements, and the
writable registers behind start, stop, current limit, boost and phase mode. A
new "modbus" control mode routes the existing control endpoints down it, so the
REST surface, the rate limit, the confirmation step and the audit trail are the
ones already there.

The commands the register map has no equivalent for say so by name rather than
failing as unknown, and a current below the charger's 6 A floor is refused
because it pauses the charge rather than slowing it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-01 17:03:27 +02:00
tajniak81andClaude Opus 4.8 19a7d48feb Harden Anker Solix OCPP control (token hashing, step-up, audit, TLS)
Security pass over the OCPP charger-control feature added in a1519f6, since
remotely actuating a physical charger is a real side effect.

Token hygiene:
  - Per-charger control tokens are stored as SHA-256 hashes + a last-4 hint,
    never plaintext. The token is shown once at generation; the status endpoint
    returns only the hint. Added a revoke endpoint that also drops any live
    session using the revoked token.

Step-up + confirmation:
  - Destructive actions (reset, unlock) require confirm:true AND a password
    re-authentication (verified against PocketBase). The Charging UI collects the
    password inline for reset.
  - Per user+charger rate limit (30/min) on control commands.

Transport + provenance:
  - OCPP_REQUIRE_TLS (default on) rejects plaintext ws:// charger connections;
    OCPP_PUBLIC_URL pins the advertised endpoint instead of trusting request
    headers.
  - Proxy-mode upstream URL is validated against a *.anker.com allowlist, so a
    spoofed ocpp-info response can't redirect the proxy.

Durable audit:
  - New control_audit PocketBase collection (added to setup-pocketbase.mjs);
    every control action, token generate/revoke and charger connect is persisted
    best-effort in addition to a structured log line.

Startup:
  - The control-token index is warmed from PocketBase on startup so a charger
    reconnecting after a restart resolves immediately.

Tests:
  - Unit tests for token hashing/eviction/revoke (no plaintext at rest),
    rate limiter, destructive-action classifier, upstream allowlist, TLS
    enforcement, and re-auth guards. A full-stack E2E (control_e2e_test.go)
    drives the real Handler with a stand-in PocketBase and a simulated charge
    point, proving step-up (400/401/200) and audit persistence end to end.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-18 21:03:05 +02:00
tajniak81andClaude Opus 4.8 a1519f6e89 Add OCPP control for the Anker Solix EV charger (Own/Proxy CSMS)
The Anker Solix connector was read-only (cloud monitoring only). Add an
OCPP 1.6J control path with a per-user, cascading control mode:

  - off   monitoring only (default, unchanged behavior)
  - own   DriverVault is the charger's Central System (full control)
  - proxy DriverVault relays to Anker's cloud and injects commands

New internal/ocpp subsystem (stdlib-only, hand-rolled RFC 6455): a CSMS
with session management, inbound dispatch, and typed control commands
(RemoteStart/Stop, SetChargingProfile current limit, ChangeAvailability,
Reset, UnlockConnector, TriggerMessage, Get/ChangeConfiguration). Own- and
proxy-mode paths are verified end-to-end against a simulated charge point.

The charger connects to /ocpp/{serial}, authenticated with OCPP Basic auth
(serial + a per-charger control token) resolved to the owning user via an
in-memory token index. Control REST endpoints mirror the monitoring ones and
reuse the same cascade gate plus a live-session check. controlMode is a new
cascade field (global -> org -> user) advertised as a select on the plugin.

Frontend: control-mode select + provisioning card in Settings, and a real
Start/Stop/limit/reset control panel in Charging, gated on the active mode.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-18 16:40:22 +02:00