Control had two transports and neither fitted the ordinary customer. OCPP waits
for the charger to dial in, which needs a public endpoint it can reach, a
certificate, and a firmware willing to talk to our CSMS. Modbus TCP dials the
charger, which needs the server on the charger's own network. Between them they
cover a charger we host and a charger we stand next to; the common case is a
charger behind someone else's router, and that had nothing.
It was never unreachable, though. The charger holds a connection open to Anker's
own broker — it is how the mobile app drives it from anywhere, and it is the
mqttStatus register the Modbus snapshot has been reporting all along. So a third
control mode joins that broker as the account: get_user_mqtt_info issues a client
certificate, mTLS to aiot-mqtt-eu.anker.com:8883, and commands go out on the same
topics the app publishes on. Nothing on the customer's side has to be forwarded,
addressed or certificated.
What travels is not an API call. The payload is a JSON envelope around a base64
binary frame the device itself speaks — marker, little-endian length, message
type, name/length/type/value fields, XOR checksum — so mqttframe.go is a codec
rather than a client, written from the message maps in anker-solix-api and
anchored on the one frame that project documents byte for byte. A frame whose
fields do not tile exactly up to the checksum is refused rather than half-read:
these arrive over a link we do not control, and a truncated frame must not read
as a charger reporting zeros.
Two of the charger's habits shape the rest. It publishes nothing unless asked, so
a status read arms a telemetry trigger and waits for the next frame, and a poll
inside that window answers from what has since arrived. And a broker connection
costs a fetched certificate and a TLS handshake while the plugin manager builds a
throwaway instance per request — so the connection lives on the account's shared
session beside the auth token, for exactly the reason the token lives there, and
closes itself after five idle minutes.
The transport also sees two signals no other one does: the boost flag, and the
plug and start countdowns. The package doc has said since the first commit that
they are never set and the derived mode must do without them. Here they are set,
so a charger that has been told to start and is counting down a delay says so
rather than sitting in "preparing", and "skip the delay" is offered only while
there is a delay to skip.
The clients generalise instead of growing a second layout. Both snapshots name
the same quantities the same way, so what was Modbus-only in the readouts is now
whichever transport read the charger — ModbusStatus becomes ChargerStatus on the
phone, mb becomes dev on the web. What each transport can be *told* still
differs, and the buttons branch on that: reset and clear-limit stay with OCPP,
the timeout and phase registers with Modbus, skip-delay with the cloud. A command
a transport has no equivalent for is refused by name, saying which one has it.
The cost is worth saying plainly. This leans on Anker's cloud being up and on an
unofficial protocol the app may change under us, where Modbus leans on nothing
but the LAN. And it is checked against the reference implementation's own worked
example rather than against hardware — there is no charger on this end to point
it at.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
The Modbus snapshot reported about half of what one poll already brings back.
The rest was read into the block and thrown away: line-to-line voltages,
reactive and apparent power per phase, the PWM flag, the control-pilot voltage,
and the identity block's product number, rated power and current range. All of
it now decodes — no extra requests, the registers were in hand already.
Added alongside it: the control block, read back over FC03. It answers a
question the live registers cannot, which is what the charger is *set* to as
opposed to what it is doing — a boost that was asked for reads there while the
live block still reports none running. Best effort, so a charger that refuses
it still reports its state.
Two registers the spec leaves blank are decoded on the hardware's evidence. The
control-pilot voltage reads 11873 while the CP signal register reports state A,
which that enum names as 12 V, so the register is millivolts. The identity
block's current range is in amps, whatever its unit column says about watts and
kVA.
The charging card lays this out in sections rather than a wall of forty numbers:
per-phase measurements as the matrix they are, then live state, then settings,
then the device itself, with alarms surfacing only when a word is non-zero.
Strings in en/da/pl.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
The two relay temperatures came back as 331 and 319 from a charger sitting idle
with nothing plugged in. The spec's gain column says 1 for both, so we reported
them as 331 °C and 319 °C — a reading that would have meant a fire rather than a
wallbox at room temperature.
The gain is 10. The same table hands the maximum current setting a unit of watts
and the timeout a unit of amps, so its unit and gain columns are not load-bearing
here; what settles the alignment is the LED brightness two registers earlier,
which reads exactly 100 at gain 1, and the fact that the neighbouring registers
all decode as tabulated. Read back from the charger afterwards: 33.1 °C and
31.9 °C.
The field becomes a float, as the voltages and currents beside it already are.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Modbus mode never returned a reading: every status poll came back as "the
charger did not answer", though the charger was answering all along. It was
refusing the question. The A5191 splits its map across two tables where the
spec's single 2xxxx column suggests one — 20000-20100 are input registers and
reject FC03 with an illegal-address exception at every address in the range,
while 21000-21005 really are holding registers and read back over FC03. We
inferred one space from the spec's layout and asked for all of it with FC03.
The client learns FC04, sharing a body with FC03 since the two differ only in
which table the server consults, and the plugin's two measurement reads move to
it. Writes stay on FC06, where the controls already live.
Confirmed against an A5191 on firmware 1.0.6.1: identity, live block and the
control registers all decode as the spec tabulates them.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
OCPP asks the charger to dial us: a public endpoint, a TLS certificate, and a
route in through the customer's router. Our own handler then demanded two more
things the V1 does not offer — TLS on a charger that connects over ws://, and
Basic auth credentials the Anker app has no field for — so every connection was
turned away before the upgrade.
Anker publishes a Modbus TCP register map for this charger, and it inverts the
problem: we dial the charger, on its own network, with no inbound reachability
to arrange. That works for a charger behind a router that OCPP cannot reach at
all.
internal/modbus is the protocol, hand-rolled against the spec like the MQTT and
WebSocket clients beside it. The plugin's modbus.go is the V1's map: the same
0-8 status enum the cloud already reports, per-phase measurements, and the
writable registers behind start, stop, current limit, boost and phase mode. A
new "modbus" control mode routes the existing control endpoints down it, so the
REST surface, the rate limit, the confirmation step and the audit trail are the
ones already there.
The commands the register map has no equivalent for say so by name rather than
failing as unknown, and a current below the charger's 6 A floor is refused
because it pauses the charge rather than slowing it.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>