Commit Graph
2 Commits
Author SHA1 Message Date
tajniak81andClaude Opus 4.8 19a7d48feb Harden Anker Solix OCPP control (token hashing, step-up, audit, TLS)
Security pass over the OCPP charger-control feature added in a1519f6, since
remotely actuating a physical charger is a real side effect.

Token hygiene:
  - Per-charger control tokens are stored as SHA-256 hashes + a last-4 hint,
    never plaintext. The token is shown once at generation; the status endpoint
    returns only the hint. Added a revoke endpoint that also drops any live
    session using the revoked token.

Step-up + confirmation:
  - Destructive actions (reset, unlock) require confirm:true AND a password
    re-authentication (verified against PocketBase). The Charging UI collects the
    password inline for reset.
  - Per user+charger rate limit (30/min) on control commands.

Transport + provenance:
  - OCPP_REQUIRE_TLS (default on) rejects plaintext ws:// charger connections;
    OCPP_PUBLIC_URL pins the advertised endpoint instead of trusting request
    headers.
  - Proxy-mode upstream URL is validated against a *.anker.com allowlist, so a
    spoofed ocpp-info response can't redirect the proxy.

Durable audit:
  - New control_audit PocketBase collection (added to setup-pocketbase.mjs);
    every control action, token generate/revoke and charger connect is persisted
    best-effort in addition to a structured log line.

Startup:
  - The control-token index is warmed from PocketBase on startup so a charger
    reconnecting after a restart resolves immediately.

Tests:
  - Unit tests for token hashing/eviction/revoke (no plaintext at rest),
    rate limiter, destructive-action classifier, upstream allowlist, TLS
    enforcement, and re-auth guards. A full-stack E2E (control_e2e_test.go)
    drives the real Handler with a stand-in PocketBase and a simulated charge
    point, proving step-up (400/401/200) and audit persistence end to end.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-18 21:03:05 +02:00
tajniak81andClaude Opus 4.8 a1519f6e89 Add OCPP control for the Anker Solix EV charger (Own/Proxy CSMS)
The Anker Solix connector was read-only (cloud monitoring only). Add an
OCPP 1.6J control path with a per-user, cascading control mode:

  - off   monitoring only (default, unchanged behavior)
  - own   DriverVault is the charger's Central System (full control)
  - proxy DriverVault relays to Anker's cloud and injects commands

New internal/ocpp subsystem (stdlib-only, hand-rolled RFC 6455): a CSMS
with session management, inbound dispatch, and typed control commands
(RemoteStart/Stop, SetChargingProfile current limit, ChangeAvailability,
Reset, UnlockConnector, TriggerMessage, Get/ChangeConfiguration). Own- and
proxy-mode paths are verified end-to-end against a simulated charge point.

The charger connects to /ocpp/{serial}, authenticated with OCPP Basic auth
(serial + a per-charger control token) resolved to the owning user via an
in-memory token index. Control REST endpoints mirror the monitoring ones and
reuse the same cascade gate plus a live-session check. controlMode is a new
cascade field (global -> org -> user) advertised as a select on the plugin.

Frontend: control-mode select + provisioning card in Settings, and a real
Start/Stop/limit/reset control panel in Charging, gated on the active mode.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-18 16:40:22 +02:00