OCPP asks the charger to dial us: a public endpoint, a TLS certificate, and a
route in through the customer's router. Our own handler then demanded two more
things the V1 does not offer — TLS on a charger that connects over ws://, and
Basic auth credentials the Anker app has no field for — so every connection was
turned away before the upgrade.
Anker publishes a Modbus TCP register map for this charger, and it inverts the
problem: we dial the charger, on its own network, with no inbound reachability
to arrange. That works for a charger behind a router that OCPP cannot reach at
all.
internal/modbus is the protocol, hand-rolled against the spec like the MQTT and
WebSocket clients beside it. The plugin's modbus.go is the V1's map: the same
0-8 status enum the cloud already reports, per-phase measurements, and the
writable registers behind start, stop, current limit, boost and phase mode. A
new "modbus" control mode routes the existing control endpoints down it, so the
REST surface, the rate limit, the confirmation step and the audit trail are the
ones already there.
The commands the register map has no equivalent for say so by name rather than
failing as unknown, and a current below the charger's 6 A floor is refused
because it pauses the charge rather than slowing it.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Security pass over the OCPP charger-control feature added in a1519f6, since
remotely actuating a physical charger is a real side effect.
Token hygiene:
- Per-charger control tokens are stored as SHA-256 hashes + a last-4 hint,
never plaintext. The token is shown once at generation; the status endpoint
returns only the hint. Added a revoke endpoint that also drops any live
session using the revoked token.
Step-up + confirmation:
- Destructive actions (reset, unlock) require confirm:true AND a password
re-authentication (verified against PocketBase). The Charging UI collects the
password inline for reset.
- Per user+charger rate limit (30/min) on control commands.
Transport + provenance:
- OCPP_REQUIRE_TLS (default on) rejects plaintext ws:// charger connections;
OCPP_PUBLIC_URL pins the advertised endpoint instead of trusting request
headers.
- Proxy-mode upstream URL is validated against a *.anker.com allowlist, so a
spoofed ocpp-info response can't redirect the proxy.
Durable audit:
- New control_audit PocketBase collection (added to setup-pocketbase.mjs);
every control action, token generate/revoke and charger connect is persisted
best-effort in addition to a structured log line.
Startup:
- The control-token index is warmed from PocketBase on startup so a charger
reconnecting after a restart resolves immediately.
Tests:
- Unit tests for token hashing/eviction/revoke (no plaintext at rest),
rate limiter, destructive-action classifier, upstream allowlist, TLS
enforcement, and re-auth guards. A full-stack E2E (control_e2e_test.go)
drives the real Handler with a stand-in PocketBase and a simulated charge
point, proving step-up (400/401/200) and audit persistence end to end.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Anker Solix connector was read-only (cloud monitoring only). Add an
OCPP 1.6J control path with a per-user, cascading control mode:
- off monitoring only (default, unchanged behavior)
- own DriverVault is the charger's Central System (full control)
- proxy DriverVault relays to Anker's cloud and injects commands
New internal/ocpp subsystem (stdlib-only, hand-rolled RFC 6455): a CSMS
with session management, inbound dispatch, and typed control commands
(RemoteStart/Stop, SetChargingProfile current limit, ChangeAvailability,
Reset, UnlockConnector, TriggerMessage, Get/ChangeConfiguration). Own- and
proxy-mode paths are verified end-to-end against a simulated charge point.
The charger connects to /ocpp/{serial}, authenticated with OCPP Basic auth
(serial + a per-charger control token) resolved to the owning user via an
in-memory token index. Control REST endpoints mirror the monitoring ones and
reuse the same cascade gate plus a live-session check. controlMode is a new
cascade field (global -> org -> user) advertised as a select on the plugin.
Frontend: control-mode select + provisioning card in Settings, and a real
Start/Stop/limit/reset control panel in Charging, gated on the active mode.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>