Commit Graph
3 Commits
Author SHA1 Message Date
tajniak81andClaude Opus 5 c1aee0fac1 One refused sign-in, not five: the chargers poll no longer locks the account
A chargers poll asks four cloud views. Each called apiRequest, each found no
token, and each ran its own login — so a login Anker refuses was offered four
times in one poll, and the next poll spent the fifth. Five is what disables the
account for ten minutes, which is how "code 26161: Failed to request." turned
into "your account has been disabled" on the very next attempt.

The plugin now remembers a refused login instead of repeating it: the failure is
cached and replayed to every caller until a backoff window passes — a minute at
first, doubling to fifteen, or the full ten minutes when Anker says it has
already locked the account (code 10019). New credentials clear it, so a fixed
password is tried at once.

chargerInventory signs in once up front. A login the cloud refuses is not four
views failing, so it is reported as itself rather than as three warnings with the
lockout notice buried in the last one.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-31 22:54:24 +02:00
tajniak81andClaude Opus 5 a809980d8b Anker health: count the chargers the panel lists, not the ones one endpoint admits to
The probe still asked get_user_bind_and_not_in_station_evchargers and read its
userBindEvChargersCount, so it reported "0 EV charger(s) bound to account" for an
account whose two chargers the panel was listing directly underneath — the same
blind spot the capability was just moved off, left behind in the health check. It
now takes the same inventory the chargers capability returns and counts that.

Authenticated with nothing on the account is degraded rather than ok, following
Greencell's rule: the half we address answers, and the empty half is the account
or the country that picks the regional server, so the message says so instead of
reporting a healthy connection to nothing. A count reached with some view missing
says how many views stayed silent, because the number is then a floor rather than
a total. The web panel colours degraded amber, as it already did for Greencell.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-31 20:46:02 +02:00
tajniak81andClaude Opus 5 e138fad3f4 Anker: every charger on the account, not just the ones outside a station
get_user_bind_and_not_in_station_evchargers is the only list the connector ever
asked for, and its name says exactly what it withholds. A charger that belongs to
a system is not in it. Its userBindEvChargersCount, though, counts every charger
bound to the account — so an owner with two chargers in a system got "authenticated;
2 EV charger(s) bound to account" from the health probe and an empty list from the
capability that is supposed to show them. A working login that finds nothing.

So the capability now asks every view the cloud has and merges them by serial. The
standalone list still answers for chargers standing on their own; get_site_list
walks the systems and reads each one through get_scen_info, falling back to
get_system_running_info where that is silent — the power-service / HES split
charger-state already knows; and get_relate_and_bind_devices contributes model,
firmware and the Wi-Fi flag, and discovers anything in the A519 family that the
first two missed. Whichever way a charger was registered, one of the three has it.

The merge is first-writer-wins per field rather than last view overwriting: the
standalone record knows the name, the site record knows the live state, and neither
should blank what the other established. A view that fails is a warning on the
document instead of an error on the call, because one dead endpoint should not
cost the chargers the other two found. Only losing all three is a failure. When
nothing comes back at all the response says so in its own words and names the
remaining suspect — country picks the regional server, and the wrong one
authenticates happily and shows an empty account.

The other half of "not showing any chargers" was that neither client ever showed a
list. The serial was a text box, and the number is printed on a charger hanging on
a wall. Both apps now list what the account holds — name, serial, model, site,
state, an offline badge — and hand the serial to the OCPP control card instead of
asking anyone to go and read it. Where control is off the list still stands on its
own, as the answer to the first question an owner has after entering credentials.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-31 20:13:36 +02:00